Email verifiedBusiness License verified

UK 6,3-HESILED 24 - Fuse modular terminal block

2024-05-20T07:02:19Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:10113154641084699985735@58qq9.8c312om

 

UK 6,3-HESILED 24 Fuse modular terminal block

3004265

Fuse modular terminal block, fuse type: Glass / ceramics / ..., fuse type: G / 6,3 x 32, nom. voltage: 24 V, nominal current: 10 A, number of positions: 1, connection method: Screw connection, Rated cross section: 1.5 mm2, cross section:  0.5 mm2- 16 mm2, mounting type: NS 35/7,5, NS 35/15, NS 32, color: black

Note regarding marking For terminal marking, please use marking material with 10.2 mm pitch.
Note regarding marking For lever marking, please use marking material with 8.2 mm pitch.

Product type Fuse terminal block
Number of positions 1
Number of connections 2
Number of rows 1
Potentials 1
Insulation characteristics
Overvoltage category III
Degree of pollution 3

Fuse type Glass / ceramics / ...
Rated surge voltage 6 kV
Maximum power dissipation for nominal condition 2.43 W
Fuse G / 6,3 x 32
Maximum power dissipation max. 2.5 W (with single arrangement of the fuse terminal block in the event of overload)
max. 1.6 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit)
max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)

Number of connections per level 2
Nominal cross section 16 mm²
Level 1 above 1 below 1
Screw thread M4
Tightening torque 1.2 ... 1.5 Nm
Stripping length 12 mm
Internal cylindrical gage B6
Connection in acc. with standard IEC 60947-7-3
Conductor cross section rigid 0.5 mm² ... 16 mm²
Cross section AWG 20 ... 6 (converted acc. to IEC)
Conductor cross section flexible 0.5 mm² ... 16 mm²
Conductor cross section, flexible [AWG] 20 ... 6 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve) 0.5 mm² ... 10 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.5 mm² ... 10 mm²
Cross-section with insertion bridge, rigid 10 mm²
Cross-section with insertion bridge, flexible 10 mm²
2 conductors with same cross section, solid 0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible 0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 0.5 mm² ... 4 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm² ... 6 mm²
Nominal current 10 A
Maximum load current 10 A
Nominal voltage 24 V
Nominal cross section 1.5 mm²
Connection in acc. with standard IEC 60947-7-3
Conductor cross section rigid 0.5 mm² ... 16 mm²
Cross section AWG 20 ... 6 (converted acc. to IEC)
Conductor cross section flexible 0.5 mm² ... 16 mm²
Conductor cross-section flexible (ferrule without plastic sleeve) 0.5 mm² ... 10 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.5 mm² ... 10 mm²
Cross-section with insertion bridge, rigid 10 mm²
Cross-section with insertion bridge, flexible 10 mm²
2 conductors with same cross section, solid 0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible 0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 0.5 mm² ... 4 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm² ... 6 mm²
Nominal current 10 A
Maximum load current 10 A
Nominal voltage 800 V (As a disconnect terminal block)
Nominal cross section 1.5 mm²
1.5 mm²

Width 10.2 mm
Height 79 mm
Depth on NS 32 65.5 mm
Depth on NS 35/7,5 60.5 mm
Depth on NS 35/15 68 mm

Color black
Flammability rating according to UL 94 V0
Insulating material group I
Insulating material PA
Static insulating material application in cold -60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg

UK 6,3-HESILED 24 - Fuse modular terminal block

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.

  • clothingclothing
    About Product:The company perennial supply Lapel T-shirt advertising , original goods of sufficient quality assurance , direct manufacturers , no" "
  • led tv repair center          samsung tcl nobel sonyled tv repair center samsung tcl nobel sony
    Introducing the best LED TV repair center in town !" "
  • Van Express MovingVan Express Moving
    If you are about to move your household or business offices , you need professional moving services NJ to help you ." "
  • Eagle Moving GroupEagle Moving Group
    Many are terrified of moving , and moving to Chicago from Florida is no exception ." "