Company: | 上海当临自动化科技有限公司 |
Location: | China - Shanghai,上海市青浦区练西公路2850号1幢 |
Price: | Negotiation |
Contact: | Jason(Manager) |
Contact Me: |
Tell:+86-19921425125 Mobile:+86-19921425125 Email:091588443584113983555115@q12q45.c1o3m |
PTFIX 4 6X1,5-NS15A GY - Distribution block
PTFIX 4/6X1,5-NS15A GY - Distribution block
1047490
Distribution block, Block with horizontal alignment and integrated supply, nom. voltage: 500 V, nominal current: 17.5 A, number of connections: 7, connection method: Push-in connection, Load contact, cross section: 0.14 mm2 - 2.5 mm2, Line contact, Rated cross section: 4 mm2, cross section: 0.2 mm2 - 6 mm2, mounting type: NS 15, color: gray
General
Note The maximum load current of a single clamping unit must not be exceeded.
For power distribution applications, IEC 60364-4-43.2008; modified + corrigendum Okt. 2008 (DIN VDE 0100-430:2010-10) section 433.2 ff must be observed!
Product type Distributor terminal block
Number of connections 7
Number of rows 1
Insulation characteristics
Overvoltage category III
Degree of pollution 3
Rated surge voltage 6 kV
Maximum power dissipation for nominal condition 0.56 W
Service Entrance yes
Number of connections per level 7
Nominal cross section 1.5 mm²
Rated cross section AWG 14
Load contact
Stripping length 8 mm ... 10 mm
Internal cylindrical gage A3
Connection in acc. with standard IEC 60947-7-1
Conductor cross section rigid 0.14 mm² ... 2.5 mm²
Cross section AWG 26 ... 14 (converted acc. to IEC)
Conductor cross section flexible 0.14 mm² ... 1.5 mm²
Conductor cross section, flexible [AWG] 26 ... 16 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve) 0.14 mm² ... 1.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.14 mm² ... 1.5 mm²
Nominal current 17.5 A
Maximum load current 22 A (with a 2.5 mm² conductor cross section)
Maximum total current 32 A
Nominal voltage 500 V
Line contact
Stripping length 10 mm ... 12 mm
Connection in acc. with standard IEC 60998-2-2
Conductor cross section rigid 0.2 mm² ... 6 mm²
Cross section AWG 24 ... 10 (converted acc. to IEC)
Conductor cross section flexible 0.2 mm² ... 4 mm²
Conductor cross section, flexible [AWG] 24 ... 10 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve) 0.2 mm² ... 4 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.2 mm² ... 4 mm²
Nominal current 41 A
Maximum load current 41 A (with 6 mm² conductor cross section)
Maximum total current 41 A
Nominal cross section 4 mm²
Load contact Connection cross sections directly pluggable
Conductor cross section rigid 0.34 mm² ... 2.5 mm²
Conductor cross-section flexible (ferrule without plastic sleeve) 0.34 mm² ... 1.5 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.34 mm² ... 1.5 mm²
Line contact Connection cross sections directly pluggable
Conductor cross section rigid 0.34 mm² ... 6 mm²
Conductor cross section, rigid [AWG] 24 ... 12 (converted acc. to IEC)
Conductor cross section flexible 0.34 mm² ... 4 mm²
Conductor cross-section flexible (ferrule without plastic sleeve) 0.2 mm² ... 4 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.2 mm² ... 4 mm²
Width 19 mm
Height 21.6 mm
Depth on NS 15 27.4 mm
Color gray
Flammability rating according to UL 94 V0
Insulating material group I
Insulating material PA
Static insulating material application in cold -60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 125 °C
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354) 27,5 MJ/kg
Surface flammability NFPA 130 (ASTM E 162) passed
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Smoke gas toxicity NFPA 130 (SMP 800C) passed
Surge voltage test
Test voltage setpoint 7.3 kV
Result Test passed
Temperature-rise test
![PTFIX 4 6X1,5-NS15A GY - Distribution block PTFIX 4 6X1,5-NS15A GY - Distribution block](https://pic.1688club.com/1247/products/eae35bda631f2581311e72a42f7f2679.jpg)
Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.
![](https://pic.1688club.com/1247/products/s_0655b39dd78bbbc69d4ba0b9e9844118.jpg)
![](https://pic.1688club.com/1247/products/s_0655b39dd78bbbc69d4ba0b9e9844118.jpg)
![](https://pic.1688club.com/1247/products/s_33020ea36a7a2a750b1802e63246c18d.jpg)
![](https://pic.1688club.com/1247/products/s_33020ea36a7a2a750b1802e63246c18d.jpg)
![](https://pic.1688club.com/1247/products/s_33020ea36a7a2a750b1802e63246c18d.jpg)
![](https://pic.1688club.com/1247/products/s_58d08ed5999200974264e39374f59dfe.jpg)
clothing
About Product:The company perennial supply Lapel T-shirt advertising , original goods of sufficient quality assurance , direct manufacturers , no" "led tv repair center samsung tcl nobel sony
Introducing the best LED TV repair center in town !" "Van Express Moving
If you are about to move your household or business offices , you need professional moving services NJ to help you ." "Eagle Moving Group
Many are terrified of moving , and moving to Chicago from Florida is no exception ." "