SACC-MINFR-3CON-PG 9 - Connector

2024-05-21T03:19:35Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:123153044109849968102558@7q13q512.c31om

 

SACC-MINFR-3CON-PG 9 Connector

1521478

Connector, Universal, 3-position, Socket angled 7/8"-16UNF, coding: A, Screw connection, knurl material: Zinc die-cast, nickel-plated, cable gland Pg9, external cable diameter 6 mm ... 8 mm

Assembly note NOTE: Observe the permissible bending radii when laying conductors, since the degree of protection may be put in jeopardy if the bending forces are too high. Alleviate mechanical loads upstream of the connector, e.g. by using cable ties.

Assembly note The wires can be connected both with ferrules and without ferrules
The connector pin assignment can be rotated 45° to the cable outlet

Product type Circular connector (cable-side)
Sensor type Universal
Number of positions 3
No. of cable outlets 1
Shielded no
Coding A
Cable outlet angled
Pg screw connection Pg9
Insulation characteristics
Overvoltage category III
Degree of pollution 3

Dimensional drawing
Length 61.1 mm
External dimensions
Outside diameter 6 mm ... 8 mm
Housing
Diameter housing 28 mm

Flammability rating according to UL 94 HB
Material of grip body PBT
Contact material CuZn
Contact surface material Au
Contact carrier material PUR/PA 6.6
Material for screw connection Zinc die-cast, nickel-plated

Conductor connection
Connection method Screw connection
Connection cross section 0.34 mm² ... 1.5 mm² (without ferrule)
0.34 mm² ... 1.5 mm² (with ferrule)
0.34 mm² ... 1.5 mm² (solid)
Connection cross section AWG 22 ... 16 (without ferrule)
22 ... 16 (with ferrule)
Stripping length of the individual wire 7 mm
Tightening torque 0.8 Nm (7/8" connectors)
0.4 Nm (Screw terminal blocks)
0.8 Nm ... 1 Nm (Pressure screw)

Rated surge voltage 4 kV
Contact resistance ≤ 5 mΩ
Insulation resistance ≥ 100 MΩ
Nominal voltage UN 300 V AC
300 V DC
Nominal current IN 12 A

Mechanical data
Insertion/withdrawal cycles ≥ 100

Connection 1
Head design Socket
Head cable outlet angled
Head thread type 7/8"-16UNF
Coding A

Signal type/category Universal
Stripping length of the individual wire 7 mm

Ambient conditions
Degree of protection IP67
Ambient temperature (operation) -25 °C ... 85 °C (Plug / socket)