Company: | 上海当临自动化科技有限公司 |
Location: | China - Shanghai,上海市青浦区练西公路2850号1幢 |
Price: | Negotiation |
Contact: | Jason(Manager) |
Contact Me: |
Tell:+86-19921425125 Mobile:+86-19921425125 Email:71015314413084797118595811@q110q.25co1m |
AXC F XT ETH 1TX - PLC extension module
AXC F XT ETH 1TX - PLC extension module
2403115
Left-alignable Ethernet interface, for connection to a compatible modular controller from the PLCnext Control range.
Width 35 mm
Height 126.1 mm
Depth 54 mm
Note on dimensions The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).
Utilization restriction
CCCex note Use in potentially explosive areas is not permitted in China.
Ethernet
Bus system RJ45
Number of interfaces 1
Connection method RJ45 jack
Note on the connection method Auto negotiation and autocrossing
Transmission speed 10/100/1000 Mbps (full duplex)
Transmission length max. 100 m
Product type I/O component
Product family PLCnext Control Extension
Type modular
Maximum power dissipation for nominal condition 1.296 W
Potentials: Supply of the logic voltage UL
Supply voltage 24 V DC
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw max. 80 mA
typ. 54 mA (at UL = 24 V)
Protective circuit Reverse polarity protection; Polarity protection diode
Transient protection; Suppressor diode
Connection technology
Connection name Axioline F connector
Conductor connection
Connection method Push-in connection
Conductor cross section rigid 0.2 mm² ... 1.5 mm²
Conductor cross section flexible 0.2 mm² ... 1.5 mm²
Conductor cross section AWG 24 ... 16
Stripping length 8 mm
Axioline F connector
Connection method Push-in connection
Conductor cross section, rigid 0.2 mm² ... 1.5 mm²
Conductor cross section, flexible 0.2 mm² ... 1.5 mm²
Conductor cross section AWG 24 ... 16
Stripping length 8 mm
Ambient conditions
Ambient temperature (operation) -25 °C ... 60 °C (up to 2000 m above sea level)
Degree of protection IP20
Air pressure (operation) 70 kPa ... 106 kPa (up to 3000 m above sea level)
Permissible humidity (operation) 5 % ... 95 % (according to DIN EN 61131-2)
Protection class III (IEC 61140, EN 61140, VDE 0140-1)
ATEX
Identification II 3 G Ex ec IIC T4 Gc
Certificate TÜV 19 ATEX 8356 X
References to standards EN IEC 60079-0, EN IEC 60079-7
IECEx
Identification Ex ec IIC T4 Gc
Certificate IECEx TUR 19.0031X
References to standards IEC 60079-0 Ed. 7, IEC 60079-7 Ed. 5.1
CCC / China-Ex
Identification Ex ec IIC T4 Gc
Certificate , 2021122309114456
References to standards GB/T 3836.1-2021, GB/T 3836.3-2021
UL Ex, USA / Canada
Identification Class I, Zone 2, AEx nA IIC T4
Class I, Div. 2, Groups A, B, C, D
Ex nA IIC Gc T4
Certificate E366272
References to standards UL 60079-0, Ed. 6 / CSA C22.2 NO. 60079-0, Ed. 3
UL 60079-15, Ed. 4 / CSA C22.2 NO. 60079-15
Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.
- Eagle Moving GroupMany are terrified of moving , and moving to Chicago from Florida is no exception ." "
- I tutor students on various subjects and also provide them free counselings based on their academicsAre you struggling with your studies Do you need extra help and guidance to excel in your academic endeavors Look no further !" "
- Enhance your skincare routine with our Vitamin C Serum in Pakistan.Welcome to Exprescents , where grooming meets sophistication and self-expression reaches new heights ." "
- Comprehensive Guide to Avast Premium Tech Support Avast HelpLooking for reliable tech support for your Avast Premium Look no further !" "