PLC-RSC- 24DC/ 1ICT/ACT Relay Module

1078680

PLC-INTERFACE for high inrush currents, consisting of PLC-BSC.../1 IC/ACT basic terminal block with screw connection and pluggable miniature relay, for mounting on DIN rail NS 35/7.5, max. inrush current up to 800 A, 1 N/O contact, 24 V DC input voltage

The relay module is particularly suitable for switching strong capacitive loads, such as LED lights. The ballasts installed in the LED lights often have extremely high switch-on peaks which cause standard relay contacts to fuse. The leading tungsten pre-contact ensures that switch-on currents of up to 800 A can be switched safely.

Notes on operation Separating plate PLC-ATP must be installed for voltages larger than 250 V (L1, L2, L3) between identical terminal blocks in adjacent modules. Potential bridging is then carried out with FBST 8-PLC... or FBST 500....
Notes on operation The PLC-ATP separating plate should be installed for safe isolation between adjacent modules
Assembly note The PLC-ATP separating plate is required at the start and end of every PLC terminal strip.
Notes on operation The system installer must ensure the touch protection of the product (at voltages > 25 V AC/60 V DC). The product is a built-in device without protection against direct contact.

Product type Relay Module
Product family PLC-INTERFACE
Application high inrush currents
Operating mode 100% operating factor
Mechanical service life 3x 107 cycles
Insulation characteristics
Insulation Safe isolation, reinforced insulation
Insulation characteristics: Standards/regulations
Insulation Safe isolation, reinforced insulation
Overvoltage category III
Pollution degree 3

Maximum power dissipation for nominal condition 0.43 W
Test voltage (Winding/contact) 4 kV AC (50 Hz, 1 min., winding/contact)
Standards/regulations
Rated insulation voltage 250 V AC
Rated surge voltage 6 kV

Coil side
Nominal input voltage UN 24 V DC
Input voltage range 20.2 V DC ... 33.6 V DC (20 °C)
() 24 V DC
Drive and function monostable
Drive (polarity) polarized
Typical input current at UN 18 mA
Typical response time 8 ms
Typical release time 10 ms
Coil voltage 24 V DC
Protective circuit Reverse polarity protection; Polarity protection diode
Freewheeling diode; Freewheeling diode
Operating voltage display Yellow LED

Switching
Contact switching type 1 N/O contact
Type of switch contact Single contact
Note regarding the switch contact With tungsten leading contact
Contact material AgSnO
Note Main contact silver tin oxide (AgSnO2): lead contact tungsten
Maximum switching voltage 250 V AC/DC
Minimum switching voltage 12 V (100 mA)
Limiting continuous current 6 A
10 A (the value is permissible if both connections 13, both connections 14 and both connections BB are bridged)
Maximum inrush current 165 A (20 ms)
800 A (200 µs)
Min. switching current 100 mA (12 V)
Interrupting rating (ohmic load) max. 144 W (at 24 V DC)
58 W (at 48 V DC)
48 W (at 60 V DC)
50 W (at 110 V DC)
80 W (at 220 V DC)
1500 VA (for 250 V AC)
Interrupting rating (ohmic load) max. bridged 240 W (for 24 V DC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.)
2500 VA (for 250 V AC. The value is permissible if both connections 13, both connections 14 and both connections BB are bridged.)
Switching capacity min. 1200 mW
Switching capacity 2 A (at 24 V, DC13)
0.2 A (at 110 V, DC13)
0.2 A (at 250 V, DC13)
6 A (at 24 V, AC15)
6 A (at 120 V, AC15)
6 A (at 250 V, AC15)

Connection method Screw connection
Stripping length 8 mm
Screw thread M3
Conductor cross section rigid 0.14 mm² ... 2.5 mm²
Conductor cross section flexible 0.14 mm² ... 2.5 mm²
0.2 mm² ... 2.5 mm² (Single ferrule)
2x 0.5 mm² ... 1.5 mm² (TWIN ferrule)
Conductor cross section AWG 26 ... 14
Tightening torque 0.6 Nm ... 0.8 Nm