Email verifiedBusiness License verified

IB IL 24 48 DOR 2 W-PAC - Relay Module

2024-05-21T06:15:30Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:6107547411284569845995@1311qq2.22co4m

 

IB IL 24/48 DOR 2/W-PAC Relay Module

2863119

Inline, Relay terminal, Relay outputs: 2 (floating), Changeover contact, 24 V AC, 48 V DC, for switching ohmic loads, transmission speed in the local bus: 500 kbps, degree of protection: IP20, including Inline connector and labeling field

The terminal is designed for use within an Inline station. It has two floating SPDT relay contacts, which are independent of one another.

Dimensional drawing
Width 12.2 mm
Height 119.8 mm
Depth 71.5 mm
Note on dimensions Housing dimensions

Inline local bus
Number of interfaces 2
Connection method Inline data jumper
Transmission speed 500 kbps

Module
ID code (dec.) 189
ID code (hex) BD
Length code (hex) C2
Length code (dec) 194
Process data channel 2 bit
Input address area 0 bit
Output address area 2 bit
Register length 2 bit
Required parameter data 3 Byte
Required configuration data 4 Byte

Relay
Number of outputs 2 (floating)
Connection method Spring-cage connection
Contact switching type Changeover contact
Switching voltage min. 10 mV (DC)
max. 30 V AC (PELV (EN 61131))
max. 60 V DC (PELV (EN 61131))
Switching current min. 10 µA
max. 2 A (30 V DC)
max. 1 A (60 V DC)
Switching capacity 60 W
62 VA (ohmic)
Limiting continuous current 2 A (at maximum ambient temperature)
Mechanical service life 2x 105 cycles

Product type I/O component
Product family Inline
Type modular
Scope of delivery including Inline connector and labeling field
No. of channels 2
Operating mode Process data mode with 2 bits
Special properties for switching ohmic loads
Insulation characteristics
Overvoltage category II (IEC 60664-1, EN 60664-1)
Pollution degree 2 (IEC 60664-1, EN 60664-1)

Potentials: Communications power (UL)
Supply voltage 7.5 V DC (via voltage jumper)
Current draw max. 30 mA
Power consumption max. 0.23 W
Potentials: Segment circuit supply (US)
Supply voltage 24 V DC (via voltage jumper)
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw max. 4 A
Electrical isolation/isolation of the voltage ranges
Test voltage: Relay contact / Bus logics 1.5 kV, 50 Hz, 1 min.
Test voltage: Contact/contact 1 kV, 50 Hz, 1 min.
Test voltage: Contact/functional ground 1 kV, 50 Hz, 1 min.

Connection technology
Connection name Inline connector
Conductor connection
Connection method Spring-cage connection
Conductor cross section rigid 0.08 mm² ... 1.5 mm²
Conductor cross section flexible 0.08 mm² ... 1.5 mm²
Conductor cross section AWG 28 ... 16
Stripping length 8 mm

IB IL 24 48 DOR 2 W-PAC - Relay Module

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.