Email verifiedBusiness License verified

UK 10-DREHSILED 24 (6,3X32) - Fuse modular terminal block

2024-05-22T01:40:51Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:01911545114886499835005@31qq10.31co4m

 

UK 10-DREHSILED 24 (6,3X32) Fuse modular terminal block

3005646

Fuse terminal block for cartridge fuse insert, cross section: 0.5 - 16 mm2, AWG: 24 - 6, width: 12 mm, color: black

Product type Fuse terminal block
Number of connections 2
Number of rows 1
Potentials 1
Insulation characteristics
Overvoltage category III
Degree of pollution 3

Fuse type Glass / ceramics / ...
Rated surge voltage 4 kV
Maximum power dissipation for nominal condition 1.82 W
Fuse G / 6,3 x 32
LED voltage range 15 V AC/DC ... 30 V AC/DC
LED current range 1 mA ... 2.5 mA
Maximum power dissipation max. 2.5 W (with single arrangement of the fuse terminal block in the event of overload)
max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of overload)
max. 4 W (with single arrangement of the fuse terminal block in the event of a short-circuit)
max. 2.5 W (With interconnected arrangement of several fuse terminal blocks in the event of a short-circuit)

LED voltage range 15 V AC/DC ... 30 V AC/DC

Number of connections per level 2
Nominal cross section 10 mm²
Rated cross section AWG 6
Level 1 above 1 below 1
Screw thread M4
Tightening torque 1.5 ... 1.8 Nm
Stripping length 11 mm
Internal cylindrical gage B6
Connection in acc. with standard IEC 60947-7-3
Conductor cross section rigid 0.5 mm² ... 16 mm²
Cross section AWG 20 ... 6 (converted acc. to IEC)
Conductor cross section flexible 0.5 mm² ... 16 mm²
Conductor cross section, flexible [AWG] 20 ... 6 (converted acc. to IEC)
Conductor cross-section flexible (ferrule without plastic sleeve) 0.5 mm² ... 10 mm²
Flexible conductor cross section (ferrule with plastic sleeve) 0.5 mm² ... 10 mm²
Cross-section with insertion bridge, rigid 10 mm²
Cross-section with insertion bridge, flexible 10 mm²
2 conductors with same cross section, solid 0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible 0.5 mm² ... 4 mm²
2 conductors with same cross section, flexible, with ferrule without plastic sleeve 0.5 mm² ... 4 mm²
2 conductors with the same cross section, flexible, with TWIN ferrule with plastic sleeve 0.5 mm² ... 10 mm²
Nominal current 10 A
Maximum load current 10 A
Nominal voltage 400 V
800 V (As a disconnect terminal block)

Width 12 mm
Height 62 mm
Depth on NS 32 62.2 mm
Depth on NS 35/7,5 57.2 mm
Depth on NS 35/15 64.7 mm

Color black
Flammability rating according to UL 94 V2
Insulating material group I
Insulating material PA
Static insulating material application in cold -60 °C
Temperature index of insulation material (DIN EN 60216-1 (VDE 0304-21)) 130 °C
Relative insulation material temperature index (Elec., UL 746 B) 130 °C
Fire protection for rail vehicles (DIN EN 45545-2) R22 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R23 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R24 HL 1 - HL 3
Fire protection for rail vehicles (DIN EN 45545-2) R26 HL 1 - HL 3
Calorimetric heat release NFPA 130 (ASTM E 1354) 28 MJ/kg
Surface flammability NFPA 130 (ASTM E 162) passed
Specific optical density of smoke NFPA 130 (ASTM E 662) passed
Smoke gas toxicity NFPA 130 (SMP 800C) passed

Mechanical data
Open side panel No

Ambient conditions
Ambient temperature (operation) -60 °C ... 110 °C (Operating temperature range incl. self-heating; for max. short-term operating temperature, see RTI Elec.)
Ambient temperature (storage/transport) -25 °C ... 60 °C (for a short time, not exceeding 24 h, -60 °C to +70 °C)
Ambient temperature (assembly) -5 °C ... 70 °C
Ambient temperature (actuation) -5 °C ... 70 °C
Permissible humidity (operation) 20 % ... 90 %
Permissible humidity (storage/transport) 30 % ... 70 %

UK 10-DREHSILED 24 (6,3X32) - Fuse modular terminal block

Disclaimer:All information is provided by registered users. You may assess risks based on corresponding qualifications.