Email verifiedBusiness License verified

GW EIP MODBUS 1E 2DB9 - Interface converters

2024-05-22T01:50:22Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:91015244413084295285845@7q20q.51co10m

 

GW EIP/MODBUS 1E/2DB9 Interface converters

1062423

The GW EIP/MODBUS... enables two-way communication between EtherNet/IP™ and Modbus protocols. Includes one RJ45 port and two D-SUB 9 ports.


Utilization restriction
EMC note EMC: class A product, see manufacturer's declaration in the download area
Utilization restriction
CCCex note Use in potentially explosive areas is not permitted in China.

Product type Interface converter
MTBF 69.4 Years (Telcordia standard, 25°C temperature, 50% stress, Environmental Factor = 1.0)
46.3 Years (Telcordia standard, 40°C temperature, 50% stress, environmental factor = 1.0)

Electrical isolation IEC UL 61010-1 (VCC // Ethernet)
Test voltage data interface/data interface 1.5 kVrms (50 Hz, 1 min.)
Test voltage data interface/power supply 1.5 kVrms (50 Hz, 1 min.)
1.5 kVrms
Supply
Supply voltage range 10.8 V DC ... 30 V DC (via pluggable COMBICON screw terminal block)
Typical current consumption 76 mA (24 V DC)
Max. current consumption 85 mA (24 V DC)
Function
Management Web-based management
Status and diagnostic indicators LEDs: Status, ACT/LNK (Ethernet data traffic)

Supply
Conductor cross section, flexible 0.20 mm² ... 2.50 mm²
Conductor cross section AWG 24 ... 12
Tightening torque 0.5 Nm ... 0.6 Nm

Signal Ethernet
EtherNet/IP™
Modbus
Web server yes
Data: EtherNet/IP™, MODBUS TCP
Serial transmission speed 10/100 Mbps, auto negotiation
Connection method RJ45 jack, shielded
No. of channels 1
Transmission length ≤ 100 m (shielded twisted pair)
Protocols supported EtherNet/IP, MODBUS ASCII/RTU/TCP
Auxiliary protocols ARP, DHCP (Client), PING
Data: RS-232
Serial transmission speed 0.3; 0.6; 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 115.2; 230.4 Kbps
Number of connections 2
Connection method D-SUB 9 plug
Pin assignment DTE
Transmission length 15 m
File format/coding 5/6/7/8 Data bits, 1/2 Stop bits, None/Even/Odd/Mark/Space Parity
Data flow control/protocols Software handshake, Xon/Xoff or hardware handshake RTS/CTS
Data: RS-422
Serial transmission speed 0.3; 0.6; 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 115.2; 230.4 Kbps
Number of connections 2
Connection method D-SUB 9 plug
Pin assignment 2, 3, 5, 7, 8
Transmission length ≤ 1200 m
Termination resistor 120 Ω (configurable)
File format/coding 5/6/7/8 Data bits, 1/2 Stop bits, None/Even/Odd/Mark/Space Parity
Data: RS-485
Serial transmission speed 0.3; 0.6; 1.2; 2.4; 4.8; 9.6; 19.2; 38.4; 57.6; 115.2; 230.4 Kbps
Number of connections 2
Connection method D-SUB 9 plug
Pin assignment 3, 5, 7
Termination resistor 120 Ω (configurable)
File format/coding 5/6/7/8 Data bits, 1/2 Stop bits, None/Even/Odd/Mark/Space Parity

Width 22.5 mm
Height 99 mm
Depth 115 mm

Color gray
Housing material PA 6.6

Ambient conditions
Degree of protection IP20
Ambient temperature (operation) -40 °C ... 70 °C
Ambient temperature (storage/transport) -40 °C ... 80 °C
Altitude < 2000 m
Permissible humidity (operation) 10 % ... 95 % (non-condensing)
Permissible humidity (storage/transport) 5 % ... 95 % (non-condensing)

GW EIP MODBUS 1E 2DB9 - Interface converters