Email verifiedBusiness License verified

IB IL INC-IN-2MBD-PAC - Function module

2024-05-22T02:05:37Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:114564312481241095985395@8q05q.6c8o10m

 

IB IL INC-IN-2MBD-PAC Function module

2819765

Inline, Position detection terminal, Incremental encoder input: 1, Symmetrical and asymmetrical encoders, Digital inputs: 3, 24 V DC, Digital outputs: 1, 0.5 A, transmission speed in the local bus: 2 Mbps, degree of protection: IP20, including Inline connectors and marking fields

Width 24.4 mm
Height 140.5 mm
Depth 71.5 mm

Inline local bus
Number of interfaces 2
Connection method Inline data jumper
Transmission speed 2 Mbps
Transmission physics Copper

Module
ID code (dec.) 127
ID code (hex) 7F
Length code (hex) 02
Length code (dec) 02
Process data channel 32 bit
Input address area 4 Byte
Output address area 4 Byte
Register length 4 Byte
Required parameter data 1 Byte
Required configuration data 5 Byte

Digital:
Input name Digital inputs
Description of the input EN 61131-2 type 1
Number of inputs 3
Connection method Spring-cage connection
Connection technology 3-conductor
Input voltage range "0" signal -3 V DC ... 5 V DC
Input voltage range "1" signal 15 V DC ... 30 V DC
Nominal input voltage UIN 24 V DC
Nominal input current at UIN typ. 2.7 mA
Encoder
Number of inputs 1 (Symmetrical or asymmetrical)
Input name Incremental encoder input
Encoder signals Symmetrical and asymmetrical encoders
Cable length max. 30 m (shielded cable, to ensure conformance with EMC Directive)

Digital:
Output name Digital outputs
Connection method Spring-cage connection
Connection technology 2-conductor
Number of outputs 1 (NPN, double assignment of input E3)

Product type I/O component
Product family Inline
Type modular
Scope of delivery including Inline connectors and marking fields
Operating mode Process data mode with two words
Insulation characteristics
Overvoltage category II (IEC 60664-1, EN 60664-1)
Pollution degree 2 (IEC 60664-1, EN 60664-1)

Encoder
Number 1
Nominal output voltage 5 V DC
Voltage range 4.75 V DC ... 5.25 V DC
Current carrying capacity max. 250 mA
Protective circuit Short-circuit protection; Electrical and thermal
Number 1
Nominal output voltage 24 V DC
Voltage range 19.2 V DC ... 30 V DC
Current carrying capacity max. 250 mA
Protective circuit Short-circuit protection; Electronic and thermal
Number max. 1 (A, /A, B, /B, Z, /Z)
Designation Symmetrical incremental encoders
Encoder supply voltage 5 V DC
24 V DC
Signal voltage level Differential signal (signal – inverted signal) ±0.5 V, minimum; ±6 V, maximum
Common mode voltage range signal - ground -10 V DC ... 13.2 V DC
Input frequency max. 300 kHz
Number max. 1 (A, B, (Z))
Designation Asymmetrical incremental encoder
Encoder supply voltage 5 V DC
24 V DC
Signal voltage level Low ≤ 2.5 V, high ≥ 3.5 V (up to 27 V, maximum)
Input frequency max. 300 kHz
Potentials: Communications power (UL)
Supply voltage 7.5 V (via voltage jumper)
Current draw max. 80 mA
Power consumption max. 600 mW
Potentials: Main circuit supply (UM)
Supply voltage 24 V DC (via voltage jumper)
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw max. 1 A
typ. 340 mA

IB IL INC-IN-2MBD-PAC - Function module