IBS IL 24 RB-T-2MBD-PAC - Communication module

2024-05-22T02:08:30Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:91110541140831349683545127@q5q43.c2o13m

 

IBS IL 24 RB-T-2MBD-PAC Communication module

2861962

Inline, branch terminal, INTERBUS, Inline shield plug, with remote bus branch, transmission speed in the local bus: 2 Mbps, degree of protection: IP20, including Inline connector and marking field

Width 12.2 mm
Height 135 mm
Depth 71.5 mm

INTERBUS
Connection method Inline data jumper
Transmission speed 2 Mbps
INTERBUS
Connection method Inline shield connector
Transmission speed 2 Mbps
Transmission physics RS-485
Inline local bus
Connection method Inline data jumper
Transmission speed 2 Mbps
Transmission physics Copper

System limits
Number of local bus devices that can be connected max. 63 (Consider the logic current consumed by the devices; the branch terminal does not count as an Inline station device.)
Module
ID code (dec.) 04
ID code (hex) 04
Length code (hex) 0
Length code (dec) 0
Process data channel 0 bit
Input address area 0 Byte
Output address area 0 Byte
Register length 0 bit
Required parameter data 0 Byte
Required configuration data 0 Byte

Product type I/O component
Product family Inline
Type modular
Scope of delivery including Inline connector and labeling field
Special properties with remote bus branch

Potentials: Supply of analog modules (UANA)
Supply voltage 24 V DC (via voltage jumper)
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw typ. 29 mA
Electrical isolation/isolation of the voltage ranges
Test voltage: 5 V supply, incoming remote bus, electrically isolated from 5 V supply, outgoing remote bus 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, incoming remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, incoming remote bus, electrically isolated from 24 V main supply, 24 V segment supply 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply incoming remote bus / functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 5 V supply, incoming remote bus 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply, outgoing remote bus, electrically isolated from 24 V main supply, 24 V segment supply 500 V AC, 50 Hz, 1 min.
Test voltage: 5 V supply outgoing remote bus, electrically isolated from functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply incoming remote bus 500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 5 V supply outgoing remote bus 500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block, electrically isolated from 24 V main supply, 24 V segment supply 500 V AC, 50 Hz, 1 min.
Test voltage: 7.5 V communications power, 24 V analog supply, 24 V bus terminal module supply, 5 V communications power, bus branch terminal electrically isolated from functional ground 500 V AC, 50 Hz, 1 min.
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, incoming remote bus 500 V AC, 50 Hz, 1 min.
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 5 V supply, outgoing remote bus 500 V AC, 50 Hz, 1 min.
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from 7.5 V logics supply, 24 V analog supply, 24 V bus terminal module supply, 5 V logics supply branch terminal block 500 V AC, 50 Hz, 1 min.
Test voltage: 24 V main supply, 24 V segment supply, electrically isolated from the functional ground 500 V AC, 50 Hz, 1 min.