Email verifiedBusiness License verified

AXL F BK EC - Bus coupler

2024-05-22T02:30:33Z 
Company: 上海当临自动化科技有限公司
Location: China - Shanghai,上海市青浦区练西公路2850号1幢
Price: Negotiation
Contact: Jason(Manager)
Contact Me:

Tell:+86-19921425125 Mobile:+86-19921425125 Email:6131511454938471298124557@12q13q73.c133om

 

AXL F BK EC Bus coupler

2688899

Axioline F, Bus coupler, EtherCAT®, RJ45 jack, transmission speed in the local bus: 100 Mbps, degree of protection: IP20, including bus base module and Axioline F connector

Width 45 mm
Height 126.1 mm
Depth 74 mm
Note on dimensions The depth applies when a TH 35-7.5 DIN rail is used (in accordance with EN 60715).

EtherCAT®
Number of interfaces 2
Connection method RJ45 jack
Note on the connection method Auto negotiation and autocrossing
Transmission speed 100 Mbps (full duplex)
Transmission physics Ethernet in RJ45 twisted pair
Axioline F local bus
Number of interfaces 1
Connection method Bus base module
Transmission speed 100 Mbps
Service
Number of interfaces 1
Connection method USB type C (from HW 05)
Micro USB type B (up to HW 04)
Fieldbus: Local bus gateway
Max. number of local bus devices 63 (Consider the logic current consumed by the devices)
EtherCAT®
System-specific protocols Mailbox protocols CAN application protocol over EtherCAT®
Mailbox protocols File access over EtherCAT®
Mailbox protocols Ethernet over EtherCAT®
Mailbox protocols Safety over EtherCAT®
Specification ETG.1000 V1.02

System limits
Number of supported devices max. 63 (per station)
Number of local bus devices that can be connected max. 63

Product type I/O component
Product family Axioline F
Type block modular
Mounting position any (observe temperature derating)
Scope of delivery including bus base module and Axioline F connector
Diagnostics messages Emergency messages
Messages via object 10F3hex Diagnosis history
Insulation characteristics
Overvoltage category II (IEC 60664-1, EN 60664-1)
Pollution degree 2 (IEC 60664-1, EN 60664-1)

Potentials: Communications power UL feed-in (the supply of the Axioline F local bus UBus is generated from UL)
Supply voltage 24 V DC
Supply voltage range 19.2 V DC ... 30 V DC (including all tolerances, including ripple)
Current draw max. 570 mA (2.0 A at UBus, UL = 24 V, up to HW 04)
max. 670 mA (2.5 A at UBus, UL = 24 V, from HW 05)
Power consumption max. 13.7 W (2.0 A at UBus, UL = 24 V, up to HW 04)
max. 16 W (2.5 A at UBus, UL = 24 V, from HW 05)
Protective circuit Surge protection; electronic
Reverse polarity protection; electronic
Potentials: Axioline F local bus supply (UBus)
Supply voltage 5 V DC (via bus base module)
Power supply unit max. 2 A (up to HW 04)
max. 2.5 A (from HW 05)
Electrical isolation/isolation of the voltage ranges
Test voltage: Ethernet interface 1 / Ethernet interface 2 1500 V AC, 50 Hz, 1 min.
Test voltage: Ethernet interface 1 / 24 V communications voltage (UL) feed-in 1500 V AC, 50 Hz, 1 min.
Test voltage: Ethernet interface 2 / 24 V communications voltage (UL) feed-in 1500 V AC, 50 Hz, 1 min.
Test voltage: Ethernet interface 1 / functional ground 1500 V AC, 50 Hz, 1 min.
Test voltage: Ethernet interface 2 / functional ground 1500 V AC, 50 Hz, 1 min.
Test voltage: 24 V communications voltage (UL) feed-in / functional ground 500 V AC, 50 Hz, 1 min.

Connection technology
Connection name Axioline F connector
Note on the connection method Please observe the information provided on conductor cross sections in the “Axioline F: system and installation” user manual.
Conductor connection
Connection method Push-in connection
Conductor cross section rigid 0.2 mm² ... 1.5 mm²
Conductor cross section flexible 0.2 mm² ... 1.5 mm²
Conductor cross section AWG 24 ... 16
Stripping length 8 mm

AXL F BK EC - Bus coupler